– one signal loop, 125 addresses and branches possibility; – Graphic LCD display with touch screen panel; – up to 64 zones; – 2 monitorеd outputs; – nonvolatile archive memory – up to 1023 events; – 1 x CAN interface; – 1 x RS232 interface; – zone dedicated LEDs indication; – programming tool for manual addressing; 20,842,193 15% 17,715,864 2 Interactive Addressable Fire Alarm panel: – Two signal loop, 250 addresses and branches possibility; – Graphic LCD display with touch screen panel; – up to 250 zones; – 2 monitored outputs; – 3 relay outputs; – nonvolatile archive memory – up to 1023 events; – 2 x CAN interfaces; – 1 x RS232. 24,838,383 15% 21,112,625 3 Interactive Addressable Fire Alarm panel: – four signal loops, 500 addresses and branches possibility; – Graphic LCD display with touch screen panel; – up to 500 zones; – 2 monitored outputs; – nonvolatile archive memory – up tp 2046 events; – 2 x CAN interfaces; – 1 x RS232 interface. 47,978,711 15% 40,781,905 4 Repeater for indication and control: – Graphic LCD display with touch screen panel; – built-in sounder; – option for power supplied Repeater panel; 22,528,807 15% 19,149,486 UNIPOS MONITORING SOFTWARE 5 Intellect – graphic software for monitoring and vizualization of IFS7000 addressable system and FS5100, FS5200 conventional panels. 33,732,261 15% 28,672,422 UNIPOS ADDRESSABLE DETECTOR & MANUAL CALL POINT 6 Fixed temperature heat detector, isolator included, with lock. 500,588 15% 425,500 7 Rate of rise heat detector, isolator included, with lock. 500,588 15% 425,500 8 Optical smoke detector, isolator included, with lock. 557,256 15% 473,668 9 Combined optical smoke and rate of rise heat detector, isolator included, with lock. 651,708 15% 553,952 10 Addressable Gas Detector for highest level of security: For detectionm of natural gas (methane in domestic premises. EN50 194-1 compliant. 1,652,881 15% 1,404,949 11 Manual call point (without transparent cover), with isolator included. 708,379 15% 602,122 UNIPOS ADDRESSABLE ZONE MODULE & IO MODULE 12 Adapter with built-in rate of rise heat detector type FD7120 and isolator included; No base included – DB7100A required. 840,608 15% 714,516 13 Adapter with auxiliary supply and two isolators included. 1,227,856 15% 1,043,678 14 Input-output device with isolator included: – 1 input; – 1 output. 826,441 15% 702,475 15 Input-output device with isolator included: – 10 inputs; – 16 outputs. 3,238,297 15% 2,752,552 16 Input-output device with two isolators included: – 3 inputs; – 6 outputs. 1,983,457 15% 1,685,938 17 Output device with two isolators inluded: – 1 output; 1,227,856 15% 1,043,678 UNIPOS ADDRESSABLE ACCESSORIESS 18 Sounder with isolator, LED indication ,“without flash” No base included – DB7100 required. 674,646 15% 573,449 19 Standard base for detector series 7100. 80,958 15% 68,814 20 Standard base for adaptor with built-in rate of rise heat detector 72001 S. 87,704 15% 74,549 21 PCB Audio Jack Phone 4,846,153 15% 4,119,230 22 Fire Telephone Jack 646,153 15% 549,230 23 Fire Telephone 646,153 15% 549,230 UNIPOS CONVENTIONAL MCFA PANEL FS4000 24 Conventional Fire Control panel: – 2 fire alarm lines; – 2 monitored outputs; – 2 relay outputs for fire; – 1 relay output for fault. 9,170,833 15% 7,795,208 25 Conventional Fire Control panel: – 4 fire alarm lines; – 2 monitored outputs; – 2 relay output for fire; – 1 relay output for fault. 9,508,156 15% 8,081,933 26 Conventional Fire Control panel: – 6 fire alarm lines; – 2 monitored outputs; – 2 relay outputs for fire; – 1 relay output for fault. 9,845,479 15% 8,368,657 27 Conventional Fire Control panel: – 8 fire alarm lines; – 2 monitored outputs; – 2 relay outputs for for fire; – 1 relay output for fault. 10,385,193 15% 8,827,414 28 Extension module for FS4000: – 2 relay outputs for fire; – interface RS485. 1,214,361 15% 1,032,207 29 Extension module for FS4000: – 4 relay outputs for fire; – interface RS485. 1,349,291 15% 1,146,897 30 Extension module for FS4000: – 6 relay outputs for fire; – interface RS485. 1,484,220 15% 1,261,587 31 Extension module for FS4000: – 8 relay outputs fo fire; – interface RS485. 1,619,149 15% 1,376,277 UNIPOS CONVENTIONAL MCFA PANEL FS5100 32 Conventional fire control panel: – 2 fire lines; – 2 monitored outputs; – 2 relay outputs for fire; – 1 relay output for fault; – LCD display; – nonvolatile archive memory – up to 84 events. 17,401,503 15% 14,791,278 33 Extension module for FS5100: – 3 fire lines; – 3 relay outputs for fire. 1,349,291 15% 1,146,897 34 Extension module for FS5100: – 6 fire lines; – 3 relay outputs for fire. 2,023,937 15% 1,720,346 UNIPOS CONVENTIONAL MCFA PANEL FS5200 & REPEATER 35 Conventional fire control panel: – 8 fire lines; – 1 monitored output; – 3 relay outputs – 2 relay outputs for fire + 1 relay output for fault; – LCD display; – nonvolatile archive memory – up to 256 events. 18,818,260 15% 15,995,521 36 Extension module for FS5200: – 8 fire lines. 3,373,226 15% 2,867,242 37 Extension module for FS5200: – 8 fire lines; – 1 monitored output. 4,047,872 15% 3,440,691 38 Extension module for FS5200: – 8 relay outputs. 2,698,580 15% 2,293,793 39 Extension module for FS5200: – 16 relay outputs. 5,059,839 15% 4,300,863 40 REPEATER: – LCD display; – 2 relay outputs – 1 relay output for fire + 1 relay output for fault; – Interface RS485. 14,417,284 15% 12,254,691 UNIPOS POWER SUPPLY 41 Power Supply Device: – input voltage (187-253) V AC, 50Hz; – maximum consumption capacity 120VA; – output voltage (17-28)V DC; – output current (in the presence of main power supply) – up tp 3.5A (continuous); – output current (in absence of main power supply and fully charged back-up battery) 3.5A up to 2h; 11,262,233 15% 9,572,898 UNIPOS CONVENTIONAL EXTINGUSHING MCFA PANEL FS5200E & ACCESSORIES 42 Fire Extinguishing Control Panel: – 3 Fire Alarm lines: 2 for extinguishing control; 1 without extinguishing control; – interface RS485. 19,155,581 15% 16,282,244 43 Module, allowing the duplication the control and indication of the extinguishing procedure. Compatible with FS5200E panel. 3,238,297 15% 2,752,552 44 Button MANUAL RELEASE; Button for manual activation of the extinguishing process. Compatible with FS5200E. 296,843 15% 252,317 45 Button EXTENSION RELEASE; Button for activation of the automatic extinguishing starting using additional source of extinguishing agent. Compatible with FS5200E. 296,843 15% 252,317 46 Button EMERGENCY STOP; Button for holding the extinguishing. It increases the evacualtion time. Compatible with FS5200E. 296,843 15% 252,317 47 MODE SELECTOR key; Key for mode selection of the FS5200E extinguishing panel work. 371,056 15% 315,398 UNIPOS CONVENTIONAL DETECTOR WITH BASE 48 Fixed temperature heat detector, with lock. 192,275 15% 163,433 49 Rate of rise heat detector, with lock. 192,275 15% 163,433 50 Optical-smoke detector with self-compensation of the optic chamber contamination, with lock. 232,754 15% 197,841 51 Combined optical smoke and rate of rise heat detector, with lock. 318,434 15% 270,669 52 Flame detector, IR, with optional lock. 1,140,152 15% 969,129 53 Manual call point (without transparent cover). 252,991 15% 215,043 54 Standard base. 74,213 15% 63,081 55 Relay base. 185,527 15% 157,698 56 Base with Schottky diode. 84,330 15% 71,681 57 Base with resistor. 78,933 15% 67,093 58 Base with Schottky diode and resistor. 91,077 15% 77,415 UNIPOS CONVENTIONAL ACCESSORIESS 59 Sounder Base 1,281,826 15% 1,089,552 60 Indoor siren – 90dB , 24V 337,323 15% 286,725 61 Outdoor siren – metal box, with flash 110dB, 12-30V. 1,221,108 15% 1,037,942 62 Indoor Conventional Sounder with Flash 337,323 15% 286,725 63 LED Remote Indicator. 74,213 15% 63,081 64 Sound Remote Indicator. 155,169 15% 131,894 65 Flanged surface mounting base accessory for FD7100 and FD8000 series detectors. 30,360 15% 25,806 66 Flangeless wet surface mounting base accessory for FD7100 and FD8000 series detectors. 91,077 15% 77,415 67 Rugged surface mounting base accessory for FD7100 and FD8000 series detectors. 30,360 15% 25,806 68 Spare Glass For FD3050 & FD7150/10 pcs. 219,260 15% 186,371 69 RS232/ 485 Interface module. 2,023,937 15% 1,720,346 70 RS LAN Interface module. 6,071,808 15% 5,161,037 71 BMS Interface Module. 7,421,098 15% 6,307,933 72 Breakable seals (5 pcs). 50,597 15% 43,008 73 Plastic transparent cover for FD7150 & FD3050. 33,733 15% 28,673 UNIPOS DUCT DETECTOR 74 Duct smoke detector with built-in conventional smoke detector and LED remote indicator. Detect the presence of smoke in air-steam of ductwork sections of ventilating compartments. 3,035,903 15% 2,580,517 75 Duct smoke detector with built-in addressable smoke detector and LED Remote indicator. Detect the presence of smoke in air-steam of ductwork sections of ventilating compartments. 3,035,903 15% 2,580,517 UNIPOS SURGE SUPPRESSOR 76 Overvoltage protection. 2,698,580 15% 2,293,793 UNIPOS CONVENTIONAL IO MODULE 77 Output relay module (8A/250VAC) for connection to a fire control panel 28 VDC outputs. 377,801 15% 321,131 78 Output relay module (8A/250VAC) for connection to a fire control panel monitored outputs. 377,801 15% 321,131 79 Output relay module (8A/250VAC) for connection to a fire detector remote indicator. 377,801 15% 321,131 80 Output relay module (4 outputs, 8A/250VAC, NO/NC) for connection to a fire control panel. 1,686,614 15% 1,433,622 81 Output relay module (8 outputs, 8A/250VAC, NO/NC) for connection to a fire control panel. 2,698,580 15% 2,293,793 82 Stunt diode safety barrier for explosion protection of hazardous areas. 8,433,065 15% 7,168,105 UNIPOS BEAM DETECTOR 83 Beam Detector 15,854,163 15% 13,476,038 84 Beam Detector Reflector till 50M 1,686,614 15% 1,433,622 85 Beam Detector Reflector till 100M 3,643,084 15% 3,096,622 UNIPOS WIRELESS FIRE ALARM SYSTEM 86 Wireless addressable fire alarm control panel: – up to 32 devices in the system; – 15 fire zones; – 2 monitored output; – 1 relay output for fire; – 1 relay output for fault; – nonvolatile archive memory – up to 4096 events; – interface RS232/485; – radio network frequency – 2.4 Ghz; – LED display 4×20 symbols, built-in sounder; – optional language for menus and messages. 25,497,247 15% 21,672,660 87 Wireless addressable Router: – performs the functions of a repeater (retransmitting the radio signlas in the network); – controls conventional sounders or fire protection and fire alarm equipment, through a programmable fire relay output; – power supplied by alternating voltage 220V/50Hz; – has a space for backup battery (not included), supporting its operation in case of fault in the main power supply 9,912,944 15% 8,426,002 88 Wireless rate of rise heat detector (base and battery included). 1,619,149 15% 1,376,277 89 Wireless optical-smoke fire detector (base and battery included). 1,889,007 15% 1,605,656 90 Wireless combined optical-smoke and rate of rise heat detector (base and battery included). 1,956,472 15% 1,663,001 91 Wireless manual call point with RE-ENABLE glass (battery included). 1,889,007 15% 1,605,656 |